MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Control Unit Problems
Power Supply Problems
Save the system programming to a memory card (beginning with
Release 3.0). See
detailed instructions. If automatic backups are performed, it may not be
necessary to save system programming.
NOTE:
If the processor module is not functioning, it may not be possible to back
up system programming.
Power Supply Problems
If the power supply fails, all components connected to the carrier are
automatically shut down.
Checking the Power Supply
If you suspect power supply failure, check the following:
Power supply LED
Interlocking post (on the carrier, behind the power supply)
Ring generator, if present
Auxiliary power unit(s), if present
!
!
WARNING:
Never remove the power supply without first turning off the power switch
and disconnecting the power cord from the AC outlet.
Use the following procedures to check the power supply.
Appendix D, ''Backing Up with a Memory
Issue 1
June 1997
Page 4-2
Card'', for
Need help?