MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Error Logs, Access Logs, and System Inventory
Error Logs
Table 2-2 Continued
Error
Codes
Description
6C09
DS1 MISFRAME ALARM:
Misframe count reached 18.
6C0A
DS1 SLIP ALARM:
Slip count reached 88.
6C0B
HARDWARE INOPERATIVE:
Hardware is not operating properly. If
this is the only 100D (DS1) or 800
CO-BRI module, or if this is the
module designated to have the active
clock, its TDM bus clock generator
was not activated.
6C0C
BRI LOSS OF SYNC:
6C0D
BRI NET DEACTIVATED:
6C0E
BRI NET INV 2B+D LB ACT:
Action
Troubleshoot the T1 trunk. If problem
persists, escalate to your technical
support organization.
Maintenance Slot Error
Events Current hr
Troubleshoot the T1 trunk. If problem
persists, escalate to your technical
support organization.
Maintenance Slot Error
Events Current hr
If problem persists, escalate to your
technical support organization.
Usually no action is required.
Troubleshoot the BRI trunk. If problem
persists, contact your technical support
organization.
Usually no action is required. The link
should return to normal once the test is
completed. If problem persists, contact
your technical support organization.
Usually no action is required. The link
should return to normal once the test is
completed. If problem persists, contact
your technical support organization.
Continued on next page
Issue 1
June 1997
Page 2-13