Lucent Technologies MERLIN LEGEND Release 5.0 Maintenance And Troubleshooting Manual page 62

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Error Logs, Access Logs, and System Inventory
Error Logs
Table 2-2 Continued
Error
Codes
Description
6C03
DS1 RED ALARM:
Incoming signal does not have valid
framing information.
Service on the link has been lost.
6C04
DS1 YELLOW ALARM:
The far end of the network interface
has lost frame synchronization.
Service on the link has been lost.
6C05
DS1 LOSS OF MULTIFRAME:
Service on the link has been lost.
6C06
DS1 REMOTE MULTIFRAME:
The far end of the network interface
is experiencing loss of multiframe.
Service on the link has been lost.
6C07
DS1 MAJOR ALARM:
Average bit error rate exceeds
10E-3.
Service on the link has been lost.
6C08
DS1 MINOR ALARM:
Average bit error rate exceeds
10E-6.
Action
Troubleshoot the T1 trunk. If problem
persists, escalate to your technical
support organization.
Troubleshoot the T1 trunk. If problem
persists, check the CSU and the DS1
configuration (the framing format). If
problem persists, escalate to your
technical support organization.
Troubleshoot the T1 trunk. If problem
persists, escalate to your technical
support organization.
Troubleshoot the T1 trunk. If problem
persists, escalate to your technical
support organization.
Troubleshoot the T1 trunk. If problem
persists, escalate to your technical
support organization.
Maintenance Slot Error
Events Current hr
Troubleshoot the T1 trunk. If problem
persists, escalate to your technical
support organization.
Maintenance Slot Error
Events Current hr
Continued on next page