MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Error Logs, Access Logs, and System Inventory
Error Logs
Table 2-2 Continued
Error
Codes
Description
0C01
NO I-VMS PORT IN SERV:
This error indicates that the VMS
machine may be down.
0C02
DID INTERDIGIT TIMEOUT:
May be noisy line or central office
problem.
1C01
POOL M-BUSY EXCEEDS 50%:
More than half the trunks in the pool
are busy.
1C02
DPR TEST NOT COMPLETED
1C03
FW UPGRADE ATTEMPT:
1C04
FW UPGRADE COMPLETE:
1C05
INVALID FMW 29 DETECTED:
Incompatibility problem. The
specified video endpoint or UDM is
connected to an 008 or 408 GS/LS
MLX with firmware vintage 0x29.
1C06
BAD BOARDS IN SYSTEM:
At least one incompatibility problem
of type HER 0x1c05 detected. Turns
on CPU red LED.
see error code 0801
1C07
2C01
T1 ACCESS VIOLATION:
T1 Services (Channels-Voice/Data)
administered incorrectly.
Action
No action required.
No action required. If problem persists,
troubleshoot the DID line and inform the
central office if necessary.
Troubleshoot trunk.
Slot did not complete initializing.
No action required.
No action required.
Replace the 008 or 408 MLX board with
one of another firmware vintage and
retire this permanent alarm manually.
Replace the 008 or 408MLX board with
one of another firmware vintage and
retire this permanent alarm manually.
Check facility provisioning and
reprogram channels appropriately for
voice or data. If the problem persists,
contact the NSAC.
Continued on next page
Issue 1
June 1997
Page 2-10
Need help?
Do you have a question about the MERLIN LEGEND Release 5.0 and is the answer not in the manual?