Central Office Problems
Trunk Errors
Outgoing Trunk Problems
If the system cannot seize outgoing trunks, try the following procedure for
analog lines.
NOTE:
You cannot perform this procedure on a rotary telephone.
Check for outside dial tone at the network interface.


For GS trunks, apply ground to the ring lead to get dial tone. If dial tone is
not present, notify the customer.
NOTE:
Steps 2 through 4 only apply to Hybrid/PBX mode. Go to Step 5 for
systems in Key or Behind Switch mode.
Pick up the handset of a test telephone to check for system dial


tone.
Dial
*03
NOTE:
If the password is not known, check the System Information Report or ask
to speak with the system manager.
You can change the password without knowing the old password only
when you perform on-site maintenance through the ADMIN jack.
Dial the 2-digit trunk number (01–80) of the trunk you want to test.


, then dial the maintenance password.