Error Logs, Access Logs, and System Inventory
Error Logs
Table 2-2 Continued
Error
Codes
Description
0012
INVALID RESET FLAG:
Processor problem.
0013
DUART STREAMING INT:
Processor problem.
0014
PROCESSOR ERR INTERRUPT:
Processor problem.
0015
MODULE MISMATCH:
Physical and logical type mismatch.
Module inserted into wrong slot.
0016
POWER UP COLD START:
A module dual port RAM failure was
detected.
System programming is okay.
0017
REAL TIME CLOCK FAULT:
Date and/or Time incorrect or
non-readable.
0018
RTC COLD START:
This error is not displayed.
0019
RESET TIME & DATE:
The system performs a cold start
because the real time clock chip is
not working correctly.
0401
ABK CARD NOT INSERTED:
A PCMCIA memory card for
Translation is not inserted.
0402
ABK INCORRECT CARD TYPE:
A PCMCIA memory card for
non-Translation is inserted.
Action
Troubleshoot the processor.
Troubleshoot the processor.
Troubleshoot the processor.
Change system programming to reflect
the proper module or install the proper
module.
If problem persists, troubleshoot the
module for the slot indicated.
If this problem persists, replace the
processor module.
If this problem persists, replace the
processor module.
Insert a Translation card or a card that
has not been formatted.
Remove the current card and insert a
Translation card or a card that has not
been formatted.
Continued on next page