MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Control Unit Problems
Module Problems
If the test fails, find the error message in
Table 4-3. Internal Loopback Test Errors
Error Messages
Slot is not busied-out
Slot empty or not valid
FMWR not in Standby
Mode
Test running too long
Not in TEST/STANDBY
mode
Any other error
NOTE:
Be sure to check the second screen if testing a 100D module or a 408
GS/LS-MLX module.
Restoring the Module
When you are finished running module tests, restore the module. See
''Restore'', earlier in this chapter.
Table 4-3
Corrective Action
Exit the test, busy-out the slot, and try again.
Exit the test and try again; be sure to type the
correct slot number. Do not indicate an empty slot
or the processor (00).
Exit the test and try again; if this error persists,
record the errors on the repair tag and replace the
module being tested.
Exit the test and try again; if this error persists,
record the errors on the repair tag and replace the
module being tested.
Exit the test and try again; if this error persists,
record the errors on the repair tag and replace the
module being tested.
Record the errors on the repair tag and replace
the module.
and proceed as indicated.