Lucent Technologies MERLIN LEGEND Release 5.0 Maintenance And Troubleshooting Manual page 61

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Error Logs, Access Logs, and System Inventory
Error Logs
Table 2-2 Continued
Error
Codes
Description
3001
ALARM TABLE FULL:
The error logs are full, and no more
errors can be added to them.
Turns on the processor LED.
4401
USER REQUESTED SYS ERASE:
This error is logged after a System
Erase. If the System Erase is
successful, this error is removed
immediately.
4402
USER REQST UPGRD/INSTALL:
This is just a record of the event.
see error code 0801
5801
6C01
DS1 LOSS OF SIGNAL ALARM:
Service on the link has been lost.
6C02
DS1 BLUE ALARM:
All unframed ones signal being
received. The link cannot be used for
communication.
Action
Correct indicated errors, and then
remove entries from the transient system
error log to free up space. If problem
persists, cold-start the system before
continuing with troubleshooting.
Sys Program System Restart
If this error remains in the transient log,
do the System Erase again. If problem
persists, troubleshoot the processor.
No action required.
Usually no action is required.
Troubleshoot the T1 trunk, channel
service unit (CSU), and the cable
between the CSU and the 100D module.
If problem persists, escalate to your
technical support organization.
Blue alarms are generated by
intermediate equipment, such as a CSU
or DDM 1000/2000. The far end of the
network interface may be out of service.
Troubleshoot the T1 trunk, channel
service unit (CSU), and the cable
between the CSU and the 100D module.
If problem persists, escalate to your
technical support organization.
Continued on next page
Issue 1
June 1997
Page 2-11