MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Control Unit Problems
800 NI-BRI Module Problems
Summary
Busy-Out or Reset
Console Procedure
PC Procedures
Appropriate Modules
Time Estimate
Interrupting the Test
Test Failure
Restore
To run the Provisioning Test, follow the steps below.
Before beginning the test, busy-out or reset the module
being tested. Both Busy-Out and Reset are in the Slot
menu, which you can access by doing the following from
the console:
Menu
Maintenance
See
''Busy-Out and
additional information.
Menu
Maintenance
Enter
Provisioning
Type the BRI slot no.
"

This test can be run only on 800 NI-BRI modules.
Approximately 20 minutes for a fully utilized board.
However, communication paths with errors increase the
time. Boards with fewer administered lines and no errors
decrease the time.
Interrupt the test by selecting
If the test fails, follow the instructions in Tables 4-6 and
4-7. If the module must be replaced, record the errors on
the repair tag and replace the module.
Restore the module when it completes all module tests.
is in the Slot menu, which you can access by
Restore
doing the following from the console:
Menu
Maintenance
See ''Restore'', earlier in this chapter, for additional
information.
Slot
Reset'', earlier in this chapter, for
Dial the BRI slot no.
Slot

.
Exit
Slot
Issue 1
June 1997
Page 4-80