MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Control Unit Problems
Module Problems
The screen below appears when either test (Test Once or Repetitive) fails.
Demand Test Slot xx :
Board aaaaaaaaaaaaaaaaaa
Board Controller Test
FAILED
xxxxxxxxxxxxxxxxxxxxxxxxx
xxxxxxxxxxxxxxxxxxxxxxxxx
Exit
Interpreting Test Results
If the test completes successfully, the module's board controller is functioning
properly. Continue with the next module test or restore the module if you are
finished testing. If the test fails, find the error message in
as indicated.
Table 4-4. Board Controller Test Errors
Error Messages
Slot is not busied-out
Slot empty or not valid
FMWR not in Standby
Mode
Test running too long
Not in TEST/STANDBY
mode
Any other error
xx = slot number entered in Step 2
Lines 5 and 6 show error messages.
If there are more than two messages,
select More to see them.
Corrective Action
Exit the test, busy-out the slot, and try again.
Exit the test and try again; be sure to type the correct
slot number. Do not indicate an empty slot or the
processor (00).
Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Record the errors on the repair tag and replace the
module.
Issue 1
June 1997
Page 4-58