Lucent Technologies MERLIN LEGEND Release 5.0 Maintenance And Troubleshooting Manual page 66

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting 555-650-140
Error Logs, Access Logs, and System Inventory
Error Logs
Table 2-2 Continued
Error
Codes
Description
7402
LOOP CONTROL BIT NOT SET:
No loop current on an outgoing call.
If this error occurs four times
consecutively, and if Automatic
Maintenance-Busy is enabled and
the 50% maintenance-busy limit has
not been exceeded, the trunk is
busied-out automatically.
7403
NO LOOP CURRENT:
Communication problems between
the module and central office.
No loop current.
If this error occurs four times
consecutively, and if Automatic
Maintenance-Busy is enabled and
the 50% maintenance-busy limit has
not been exceeded, the trunk is
busied-out automatically.
7404
STUCK RINGING:
Communication problems between
the module and central office.
If this error occurs twice
consecutively, the trunk is busied-out
automatically, whether or not
Automatic Maintenance-Busy is
enabled.
7801
NOT IN NORMAL OP MODE:
Module not in normal operation
mode. Reported in background
module check.
Action
Test the trunk with a single-line
telephone. If the problem is not in the
trunk, replace the module with one that is
known to be working. If the problem is
gone when using the known good
module, replace the module and restart.
Test the trunk with a single-line
telephone. If the problem is not in the
trunk, replace the module with one that is
known to be working. If the problem is
gone when using the known good
module, replace the module and restart.
Test the trunk with a single-line
telephone. If the problem is not in the
trunk, replace the module with one that is
known to be working. If the problem is
gone when using the known good
module, replace the module and restart.
Reset the board . If problem persists,
troubleshoot the module.
Maintenance Slot Slot
Number Reset
Continued on next page
Issue 1
June 1997
Page 2-16