Measurement Parameters (Shape Search+)
Specify the shape search+ measurement conditions and the judgement conditions for the measurement
results.
1.
In the Item Tab area, tap [Measurement].
2.
In the "Measurement condition" area, specify a value for each item.
Setting item
Candidate
30 to 100
level
[50]
Corr. ascending
●
[Corr. descending]
●
Sort
X ascending
●
condition
X descending
●
Y ascending
●
Y descending
●
Search No.
[0] to 99
3.
You can set the following conditions details by tapping [Detail setting].
Setting item
Count
Subpix level
FZ3 Processing Items List Manual
Set value
[factory default]
Specify the threshold value with which to detect
candidate points in a rough search.
Specify a smaller value when model search results are
unreliable.
Set the sorting method for the measurement results.
Input the search number for outputting the data.
Set value
[factory default]
[1] to
[Fast]
Normal
Precise
Description
Description
Specify the number of targets to be detected.
This is set when measuring the position
information in sub-pixel units.
To emphasize precision, select [Precise].When
[Precise] is selected, this requires more
processing time.
Shape Search+
99