Verification Parameters (Date Verification) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Set this to print the date encrypted in such a way that it is difficult for the user to recognize.Setting
Code
what codes show also makes possible automatic updating.
parameter
Reference:
This item can be changed if necessary.Normally, the factory default value will be used.
Output
Use the output parameter to specify how to handle the coordinates.
parameter
Reference:

Verification Parameters (Date Verification)

This item sets the verification target and the verification source character string.
The character string read in Character Inspection is the target for verification.
1.
In the Item Tab area, tap [Verification].
2.
This item sets the general OCR unit for verification.
Note
Always set Character Inspection in a unit before the Date Verification unit.
3.
In the "Target string setting" area, tap [...] for "Target string expression".
The String setting dialog is displayed.
4.
This item sets the character string that is the source for verification.
Input the date format and the preceding and following character strings.
FZ3 Processing Items List Manual
Code Parameters (Date Verification) (p.248)
Output Parameters (Date Verification) (p.251)
Date Verification