Measurement Results For Which Output Is Possible (Defect) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

When the measurement results are unstable
Noise is detected as defects.
Parameter to be adjusted
Measurement
2
Judgement will be NG.
Parameter to be
adjusted
Measurement
When the processing speed is slow
Parameter to be
adjusted
Measurement

Measurement Results for Which Output Is Possible (Defect)

The following values can be output using processing items related to results output.It is also possible to
reference measurement values from expressions and other processing units.
Measurement items
Judgement
Defect
Position of defect
Position of defect
Defect area
Defect gravity
Defect gravity
216
Defect
Specify a larger value for "Defect judgement" in the judgement conditions.
Make the measurement region larger than the lower limit of the defect size.Or make the lower
limit of the defect detection size smaller than the measurement region.
Specify a larger value for the "Defect size".
Reduce the difference between the upper and lower limits of "Defect size".
Character
string
JG
Judgement result
F
Measured defect level
X
X Coordinate of measured defect position
Y
Y coordinate of measured defect position
AR
The measured maximum defect area
GX
The center of gravity X coordinates of the measured maximum defect area
GY
The center of gravity Y coordinates of the measured maximum defect area
Remedy
Remedy
Remedy
Description
FZ3 Processing Items List Manual

Advertisement

Table of Contents
loading

Table of Contents