Omron XPECTIA FZ3 User Manual page 297

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

2.
Set each item while checking the image.
Set value
Setting item
[Factory default]
Through image
display
Display
[Freeze image
display]
[Camera image]
Target for
filtering
Previous image
[Filtering →
Order of
BGS ]
BGS →
filtering
Filtering
FZ3 Processing Items List Manual
Description
The latest image is always input from the camera and displayed.
The image that was scanned in the immediately preceding
measurement is displayed. Images can be updated at any time
during measurement.
Filtering is applied to the images input from the camera that is set
before this unit ( [Filtering]) in the scene. Filtering is not
performed.
Filtering is applied to the images which have been processed by
the [Position Compensation] and [Filtering] units that are set
before this unit ( [Filtering]) in the scene.
Select the sequence of background suppression/filtering.
Filtering