Output Parameters (Sensitive Search) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Candidate
0 to 100
level
[60]
Sub-region
0 to 10
margin
[6]
3.
When the setting has been changed, tap [Measurement] in the Detail area to verify whether
measurements can be made correctly.
4.
Set up the judgement condition.
Setting item
Set value
-99999.9999
Measure X
to
99999.9999
-99999.9999
Measure Y
to
99999.9999
Search
-180 to 180
angle
Correlation
0 to 100
Deviation
0 to 221
NG
0 to 100
Sub-region

Output Parameters (Sensitive Search)

Specify how to treat the coordinates to be output to the external device as measurement results.This
item can be changed if necessary.Normally, the factory default value will be used.
1.
Tap [Output parameter] in the Item Tab area.
FZ3 Processing Items List Manual
Specify the threshold value with which to detect candidate points
in a rough search.Specify a smaller value when model search
results are unstable.
This is set when expanding the measurement region for
sub-region measurement.Specify a larger value when model
search results are unstable.
Specify the range of X-axis shifting that is judged to be OK.
Specify the range of Y-axis shifting that is judged to be OK.
Specify the range of angles that are judged to be OK.
Specify the range of correlation values that are judged to be
OK.However, when the correlation value of the measurement result is
0, the judgement result will be NG regardless of the lower limit setting.
Specify the range of density deviations that are judged to be OK.The
higher the proportion of plain sections, the higher this value.
This is enabled when plain inspection is set in the sensitive model
settings.
Specify the range of NG sub-region that are judged to be OK.
Description
Sensitive Search
2
69

Advertisement

Table of Contents
loading

Table of Contents