4.
If necessary, set each item in the "Noise removal" area.
2
Setting item
Noise level
Noise width
5.
In the "Approximate line" area, specify the point to be used for the calculation of approximate
lines.
Noise cancel

Judgment Conditions (Scan Edge Position)

Specify the range to be judged as OK.
140
Scan Edge Position
Set value
[factory
default]
0 to 442
When detection is affected by noise, increase this value.
[5]
Reference:
Set the width for judging noise.
0 to 9999
When detection is affected by noise, increase this value.
[0]
Reference:
Set value
Setting item
[factory
default]
ON
[OFF]
Description
See "User's Manual", "Noise level" (p.305)
See "User's Manual", "Noise width" (p.306)
Description
When a check is placed at [ON], an approximate line is
found by excluding the points with large deviation
among the measured points.