4
Point coordinate X, Y
Actual coordinate X, Y
4.
Subsequently set up in the same manner.
5.
Tap [Generate calibration parameters].
The calibration parameters will be generated.
Setting Calibration through Sampling Measurement (Sampling)
This is a method for setting calibration based on measurement results.
Calibration parameters are calculated automatically when a registered model is searched and the actual
coordinates for that position entered.
1.
In the "Calibration setting" area, select "Sampling".
350
Calibration+
Actual coordinate
If this succeeds,
the Calibration parameter status changes from "The parameter is not generated" to "The
parameter is the latest".
If this fails,
"Failed to generate parameters" is displayed.
Set value
[Factory default]
0.0000 to 9999.9999
[Point you tapped in the window]
-99999.9999 to 99999.9999
[0]