Date Parameters (Date Verification)

This item sets the date/time format and update conditions.
1.
In the item tab area, tap [Date parameter].
2.
When comparing with character strings with an expiration date limit, set each item in the "Period
setting" area.
Setting value
Setting item
[Factory default]
0 to 99
Year
[0]
0 to 99
Month
[0]
0 to 999
Day
[0]
3.
In the "Date setting" area, specify a value for each item.
Setting value
Setting item
[Factory default]
Not update
First measure
Auto Update
[Always
update]
Zero
[0]
suppress
Space
FZ3 Processing Items List Manual
Description
This item sets the usage period from the current date.
Example) When the current date is Oct. 1, 2007 and the usage
period is 10 days, the expiration date is Oct. 11, 2007.
Description
Set the year, month and day updating conditions. The clock
time is always updated.
Not update: The date is stored into memory when the
processing unit is registered. The date is not updated until
the next time date update is executed with the menu.
First measure: The date is updated during the first
measurement after start up.
Always update: The date is updated every measurement.
Set how the tens digits of the month and day are displayed.