2.
Use the drawing tools to specify the model registration range.
2
3.
This sets the model parameter.
Angle range
Reverse
Size change
4.
When the "Size change" option is checked, tap [Detail setting].
The "Model parameter: Size change" area is displayed.
Move axis
Move range
5.
Tap [Return].
The "Model parameter" area is displayed.
Important
Set the region such that the number of pixels in the model region is 995328 pixels or less.
Sometimes detection exceeds the set angle range.
When the angle range is set and the image registered as a model is measured, some error occurs in the
rotation angle.
96
Shape Search+
Set value
Setting item
[factory default]
-180 to 180
Upper limit
[0]
-180 to 180
Lower limit
[0]
Checked
[Unchecked]
Checked
[Unchecked]
Set value
Setting item
[factory default]
[XY]
X
Y
Upper limit
[100] to 110
Lower limit
90 to [100]
Description
When the measurement object is rotating, set
how large the angle range is for creating rotated
models.The skipping angle is set automatically.
Specify whether to allow the reverse of light and
dark for the model.
This is set when the size of measurement
objects changes. When checked, tap [Detail
setting] and specify a value for each item.
Description
Specify the model variable direction.
Specify the range in which to change the
model size.