Additional Explanation (Data Logging)

When 9 or More Data Items Are Output as One Record
Up to 8 Value can be output with one [Data Logging] Processing Item. When 9 or more data items are to
be output as 1 record, perform settings in the following manner.
Registers two or more [Data Logging] units in one scene.(*1)
Set [File name] of [Data Logging] so that it is identical.(*2)
This prepares set up to attach "Record separator (CR+LF)" to the end of all data output.(*3)
4
Example) When outputting the coordinate data for 12 points acquired in two "Search" of
measurements performed on substrate arrangement in 1 record.
Unit 3 [Data logging] setting details
<Condition setting>
Output Destination
(File name)
Integer
Decimal
Measurement ID
Minus
0 suppress
Field separator
Record separator
<Output data>
384
Data Logging
Unit 4 [Data logging] setting details
<Condition setting>
Output Destination
datalog.csv
(File name)
8
Integer
3
Decimal
ON
Measurement ID
-
Minus
OFF
0 suppress
Comma
Field separator
Comma
Record separator
<Output data>
Remarks
(*2)
Make the path
datalog.csv
and file name
the same.
8
3
ON
-
OFF
Comma
(*3)
Set "Record
separator
CR+LF
(CR+LF)" in
unit 4 which
contains the
last data