Omron XPECTIA FZ3 User Manual page 203

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

When the Sort Condition is other than gravity XY, Inscribed circle XY and Circum. circle XY
Setting item
[Factory default]
[Area]
Gravity X
Gravity Y
Gravity XY
Elliptic axis angle
Elliptic major axis
Elliptic minor axis
Elliptic ratio
Rectangle width
Rectangle height
Rectangle X1
Rectangle Y1
Perimeter
Sort method
Circularity
Fit rect major axis
Fit rect minor axis
Fit rect ratio
Inscribed circle X
Inscribed circle Y
Inscribed circle XY
Inscribed circle R
Circum. circle X
Circum. circle Y
Circum. circle XY
Circum. circle R
Number of holes
Ascending
Sort order
[Descending]
Label No.
[0] to 2499
FZ3 Processing Items List Manual
Set value
Specify the conditions by which label number is
re-assigned.
The label number is assigned according to the value of the
selected feature quantity.
When gravity XY, Inscribed circle XY, or Circum. circle XY
is selected, grouping is performed in the vertical or
horizontal direction and labels re-assigned within those
groups.
This is used for assigning numbers to labels lined up in a
grid.
Set the direction for sorting.
Ascending: Numbers are assigned from smaller values to
larger.
Descending: Numbers are assigned from larger values to
smaller.
Input the label number for the data to be output.
Description
Labeling+
2
201

Advertisement

Table of Contents
loading

Table of Contents