Omron XPECTIA FZ3 User Manual page 224

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Setting item
Defect color
(for
monochrome
cameras
only)
2
Area
measurement
Area meas.
LV
4.
When the setting has been changed, tap [Measurement] in the Detail area to verify whether
measurements can be made correctly.
5.
Set up the judgement condition.
Setting item
Defect judge
Area judge
6.
If necessary, set the display conditions for displayed images.
222
Precise Defect
Set value
[Factory default]
Select this value when defects look blackish compared to the
Black
background.
Select this value when defects look whitish compared to the
White
background.
[Both white / black]
Select this value when the brightness of defects is not known.
Place a check when you want to measure the size of
defects.This item can divide the high defect detection regions
Checked
into groups and output the surface and center of gravity
[Unchecked]
coordinates of the group with the largest area.
However, when only one region is specified with "Wide line",
"Wide circle", or "Arc", area measurement is not possible.
0 to 999
If you place a heck at Area Measurement, set defect level
[100]
counted in the defect area.
Set value
[Factory
default]
Specify the upper limit for defect judgement. (The lower limit is fixed at
0 to 999
0.)
[100]
When "30" is set, the OK value should be within the range of 0 to 30.
Specify the maximum defect area.
0 to
A_MAX: 307,200 for a 0.3-megapixel camera, 1,920,000 for a
[999999999.9999]
2-megapixel camera, 4,320,000 for a 5-megapixel camera
Description
Description
FZ3 Processing Items List Manual