1
Origin
Magnification
4.
Tap [Generate calibration parameters].
The calibration parameters will be generated.
View Calibration Parameters
View the set calibration data.
1.
In the Item Tab area, tap [Calibration].
2.
In the "Calibration parameter" area, confirm the calibration data.
Item
A
B
C
D
E
F
30
Camera Image Input
Select where the origin of the actual coordinates will be.
[Upperleft],
Lowerleft, Center
0.00001 to
Specify the ratio of 1 pixel to the actual dimensions.
9.99999
Set value
Calculation value
These are calibration conversion values. Camera coordinates are
Calculation value
converted to actual coordinates based on these values. The
conversion formulas for actual coordinates are as follows:
Calculation value
(X, Y): Measurement point (camera coordinates), Unit: pix
●
Calculation value
(X', Y'): Conversion point (actual coordinates)
●
Calculation value
X'=A x X + B x Y + C
Calculation value
Y'=D x X + E x Y + F
Description
FZ3 Processing Items List Manual