Omron XPECTIA FZ3 User Manual page 141

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Setting item
[factory default]
0 to 99
Edge No.
[0]
Position (%) for
width of a color
Edge level
0 to 100 [50]
Value of color
0 to 442 [20]
Edge color
0 to 442
level
[100]
For monochrome cameras:
Set value
Setting item
[factory default]
Measure
[ Projection]
type
Derivation
[Light → Dark]
Density
Dark → Light
change
0 to 99
Edge No.
[0]
Position (%)
for width of a
density
Edge level
0 to 100 [50]
Value of
density
0 to 255 [20]
FZ3 Processing Items List Manual
Set value
Specify the edge number used to extract edges.
Edge numbers are assigned to detected edges starting from 0
and going on in the direction from the start point (the arrow
point) to the end point (the direction of arrow) in the selected
area.
Select a color difference level with which the edge is detected.
Reference:
This emphasis level can be specified only if the edge color to
detect is specified.
This sets the type of edge measurement.
Select whether a black-to-white change or a white-to-black
change should be recognized as a density change in the
specified region.
Specify the edge number used to extract edges.
Edge numbers are assigned to detected edges starting from 0
and going on in the direction from the start point (the arrow point)
to the end point (the direction of arrow) in the selected area.
Select the density change level to be detected as edges.
Reference:
See "User's Manual", "Edge level" (p.304)
Description
See "User's Manual", "Edge level" (p.304)
Description
Scan Edge Position
2
139