Output Parameters (Scan Edge Position) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Long
distance
Min.
Short
distance
Max.
Short
2
distance
Min.
Deviation
Line angle
Lost point
count
* dist (X_MAX,Y_MAX) = sqrt (X_MAX*X_MAX+Y_MAX*Y_MAX)

Output Parameters (Scan Edge Position)

Specify how to treat the coordinates to be output to the external device as measurement results.This
item can be changed if necessary.Normally, the factory default value will be used.
Important
After setting up the measurement parameters, changing the output parameters will cause measurement results
to vary accordingly.If the output parameters have been changed, re-specify the measurement, too.
1.
Tap [Output parameter] in the Item Tab area.
2.
Specify each of the following items.
Setting item
Output
Coordinates
Calibration
142
Scan Edge Position
0 to dist
Specify the upper and lower limits of the long distance
(X_MAX,Y_MAX)
minimum judged to be OK.
0 to dist
Specify the upper and lower limits of the short distance
(X_MAX, Y_MAX)
maximum judged to be OK.
0 to dist
Specify the upper and lower limits of the short distance
(X_MAX, Y_MAX)
minimum judged to be OK.
0 to dist
Specify the upper and lower limits of the deviation judged
(X_MAX, Y_MAX)
to be OK.
Specify the upper and lower limits of the line angle judged
-180 to 180
to be OK.
Specify the upper and lower limits of the lost point count
0 to 100
judged to be OK.
Set value
[factory
default]
[After
As measurement results, select whether to output coordinate values
scroll]
to external devices before or after the position deflection correction is
Before
applied.
scroll
Select whether to reflect the calibration in the values output to the
[OFF]
external device as measurement results.
ON
ON: Output the coordinates converted into actual dimensions.
OFF: Output the camera coordinate values.
Description
FZ3 Processing Items List Manual

Advertisement

Table of Contents
loading