2.
Specify each of the following items.
2
Setting item
Output
Coordinates
Calibration
Reflect to
overall
judgement

Key Points for Test Measurement and Adjustment (Labeling+)

In addition to the judgement, the contents of feature quantities 0-7 specified with the judgement
condition tab are displayed in the "Detail result" area.
Judge
Key Points for Adjustment
Select the adjustment method referring to the following points.
When the measurement results are too unstable for extraction
For color cameras:
Parameter to
be adjusted
Color
206
Labeling+
Set value
[Factory
default]
[After
As measurement results, select whether to output coordinate values
scroll]
to external devices before or after the position deflection correction is
Before
applied.
scroll
Select whether to reflect the calibration in the values output to the
[OFF]
external device as measurement results.
ON
ON: Output the coordinates converted into actual dimensions.
OFF: Output the camera coordinate values.
[ON]
Enables choosing whether or not the judgement result of this
OFF
processing unit is reflected in the scene overall judgement.
Displayed items
Tap the area whose color will be sampled and the area whose color will not be sampled. The setup
should be such that two stable sections of hue, saturation and brightness are formed.
Or place a check at More ranges of color extraction and multiple colors are specified.
Description
Description
Judgement result
Remedy