Omron XPECTIA FZ3 User Manual page 176

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

This section describes how to specify colors in an image and gives an example of the procedure for
finely adjusting with numeric input afterwards.
1.
In the Item Tab area, tap [Color].
2.
Place a check at [Auto setting].
3.
In the Image Display area, specify the color range you want to detect by dragging the cursor from
the upper left corner to the lower right corner of that area.
2
The color of the specified area is automatically set.
4.
Finely adjust the hue, saturation, and brightness if necessary.
Adjust either by adjusting on the color chart or by inputting numbers.
Item
H
S
V
Auto setting
Color inv.
174
Labeling
Set value
[Factory default]
0 to 359
Specify the color phase (difference of color hues).
0 to 255
Specify color saturation (difference of color saturation).
0 to 255
Specify the brightness (difference of brightness).
Checked
Specifying the color to be measured on the image automatically
[Unchecked]
sets the hue, saturation, and brightness.
Checked
Everything other than the specified color becomes the
[Unchecked]
measurement target.
Description