Omron XPECTIA FZ3 User Manual page 320

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

2.
In the "Display" area, tap [Change display] to switch between camera image types.
The displayed contents of the Image Display area will be switched.
Setting item
3
Display
3.
Set each item in the "Filter parameter" area.
Setting item
RGB ratio
Gain
4.
As necessary, check the image after conversion.
Setting item
Filtered image
318
Halation Cut+
Set value
[Factory default]
The latest image is always input from the camera and
Through image display
displayed.
The image that was scanned in the immediately preceding
[Freeze image display]
measurement is displayed.
Set value
[Factory
default]
Adjust the balance of the red brightness and blue brightness for the
shot image.
-100 to 100
Specifying a larger value in the positive direction (R direction) makes
[0]
the R component easier to suppress.
Specifying a larger value in the negative direction (B direction) makes
the B component easier to suppress.
0.0001 to
9.9999
Adjust the gain for compensating the brightness of the output image.
[1.0000]
Set value
[Factory default]
[Checked]
Unchecked
Description
Description
Description
To display the original image, uncheck
here.
FZ3 Processing Items List Manual

Advertisement

Table of Contents
loading