2
6.
To register two or more models, repeat the Steps Reference: 3(p.255) to Reference: 5(p.255) .
Changing Model Parameters
Model parameter values can be changed as needed to address unstable measurement results or to
increase the processing speed.Normally, the factory default value will be used.
After changing a setting, check whether measurement can be done properly by performing an actual
measurement.
Important
After model parameters are modified, re-register all models.
1.
In the "Model parameter" area, specify a value for each item.
Rotation
Smart mode
256
Model Dictionary
Set value
Setting item
[Factory default]
Checked
[Unchecked] When the measurement object rotates, place a
-45 to 45
Angle range
[0]
[Checked]
Unchecked
Description
check at "Rotation" and set the Angle range during
a search.The normal direction is clockwise.
Checking the "Smart mode" option enables a
high-speed rotation search.The stability may be
lowered when the model shape aspect ratio is large
or when the NOT mask is used.