Omron XPECTIA FZ3 User Manual page 215

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

For monochrome cameras:
Set value
Setting item
[Factory default]
Area
Checked
measurement
[Unchecked]
Area defect
0 to 999
level
[20]
Black only
Defect color
(for
White only
monochrome
cameras
[Both white &
only)
black]
FZ3 Processing Items List Manual
Description
Place a check when you want to measure the size of
defects.This item can divide the high defect detection regions
into groups and output the surface and center of gravity
coordinates of the group with the largest area.
However, when only one region is specified with "Wide line",
"Wide circle", or "Arc", area measurement is not possible.
If you place a heck at Area Measurement, set defect level
counted in the defect area.
Select this value to detect defects that look darker than the
background.
Select this value to detect defects that look lighter than the
background.
Select this value when the brightness of defects is not known.
Defect