Output Parameters (Parallel Judgement Output) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

2.
In the list, tap the output No. for which the expression is to be set.
The selected output No. is displayed under the list.
3.
Tap [...] for the expression and set the expression.
Reference:
Layout of Setting Expression Window (p.333)
4.
In "Judgement condition", set the judgement upper limit and lower limit.
Setting item
Judgement
-999999999.9999 to
condition
999999999.9999
5.
Input an explanation of the expression in "Comment" as necessary.
6.
Repeat steps Reference: 2(p.419) to Reference: 4(p.419) and set up the output contents for each output number.

Output Parameters (Parallel Judgement Output)

Specifies whether or not the judgement result of this processing unit is reflected in the scene overall
judgement.
1.
Tap [Output parameter] in the Item Tab area.
2.
Choose whether or not to reflect this in the scene overall judgement in "Reflect to overall
judgement" area.
Setting item
Reflect to overall
judgement
FZ3 Processing Items List Manual
Set value
This is a judgement condition for the expression. Specify
the upper/lower limits to be judged as OK.
Set value
[factory
default]
[ON]
Enables choosing whether or not the judgement result of this
OFF
processing unit is reflected in the scene overall judgement.
Description
Description
Parallel Judgement Output
6
419

Advertisement

Table of Contents
loading

Table of Contents