Programming Commander DELTA
Icon
Parameter
Parameters Seam Begin
Scan Mode
(Access only after activation in the
machine configuration)
Seam begin bartack parameters
Bartack at seam begin
Number of stitches backwards
Number of stitches forward
Number of bartack sections
A bartack consists of several sections. If the
sewing direction is changed, a new section
is started. The number of sections in a
bartack can be set here.
Stop-Time for direction change
The waiting time at the turning points
(e.g. for a change of sewing direction)
is set at this point. A short waiting time in
milliseconds should ensure consistent seam
quality (ornamental-stitch bartack).
Operating Instructions D888 e-con - 00.0 - 12/2023
5.9.6
Setting the Seam Begin/Segment Begin
parameters
There are various options for setting the Seam Begin/Segment
Begin parameters. The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
Settings
Value range
Read & Compare/Read & Store/Off
Value range
On/Off
Value range
01 – 50 [stitches]
Value range
01 – 50 [stitches]
Value range
01 – 99
Value range
0000 – 1000 [ms]