Dürkopp Adler D888 e-con Operating Instructions Manual page 218

Table of Contents

Advertisement

Code
Type
2573
Error
2574
Error
2575
Error
2576
Error
2577
Error
2578
Error
2579
Error
2580
Error
2581
Error
2583
Error
2584
Error
2585
Error
2587
Error
216
Possible cause
Stepper card X70 sewing
motor encoder not connected
(Upper puller)
Stepper card X70 sewing
motor encoder not initialized
(Upper puller)
Stepper card X70 init position
not found (Upper puller)
Stepper card X70 not
enabled (Upper puller)
Stepper card X70 overload
(Upper puller)
Stepper card X70 encoder
failure (Upper puller)
Stepper card X70 Current
sensor failure (Upper puller)
Stepper card X70 Incorrect
stepping motor direction of
rotation (Upper Puller)
Stepper card X70 reference
drive failure (Upper puller)
Stepper card X70 overcurrent
(Upper puller)
Stepper card X70 parameter
initialization (Upper puller)
Stepper card X70 insulation
error (Upper puller)
Stepper card X70 transport
interval failure (Upper puller)
Corrective
• Replace the control
• Perform software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace encoder
• Replace the control
• Replace encoder
• Check if plugs have been mixed up
• Check the wiring in the machine distribu-
tor and change it if necessary
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
• Perform software update
• Check selection of class
• Check motor phase and PE for low-
impedance connection
• Replace encoder
• Replace sewing motor
• Perform software update
• Check selection of class
Operating Instructions D888 e-con - 00.0 - 12/2023
Troubleshooting

Advertisement

Table of Contents
loading

Table of Contents