Dürkopp Adler D888 e-con Operating Instructions Manual page 222

Table of Contents

Advertisement

Code
Type
3223
Information No loop (right)
3224
Information Bobbin Rotation Monitor
3225
Information SSD sensor is soiled
3226
Information No loop (left)
3227
Information Bobbin Rotation (left)
3228
Information Clean Loop Control sensor
3354
Information Failure in thread trimmer
3383
Information Failure in the motor
220
Possible cause
(left)
process
referencing process
Corrective
Skip stitch monitor
• The sensor of the skip stitch monitor
detected during the sewing process that
the loop of the needle thread was not
taken up, resulting in a "skip stitch".
• The bobbin is not rotating
• Check the bobbin, advance the initial
thread
• Use compressed air or a soft cotton cloth
to clean the sensor
Skip stitch monitor
• The sensor of the skip stitch monitor
detected during the sewing process that
the loop of the needle thread was not
taken up, resulting in a "skip stitch".
Bobbin Rotation Monitor
• The sensor of the bobbin rotation monitor
detected during the sewing process that
no hook thread was consumed and that
the seam was apparently not created
properly.
Sensors soiled
• The optical sensors for the skip stitch
monitor, the bobbin rotation monitor and
the remaining thread monitor are soiled
and deliver no reliable signal.
Please clean dirt off the sensors using
compressed air or a soft brush.
• Perform software update
• Check motor
• Perform software update
Operating Instructions D888 e-con - 00.0 - 12/2023