Code
Type
9310
Error
9320
Error
9330
Information Material thickness sensor
9340
Information Remaining thread monitor
9341
Information Bobbin control (left) not
9350
Error
9351
Error
9352
Error
9353
Information Needle thread tension sen-
9354
Error
9360
Error
9361
Error
228
Possible cause
Tape feeder not connected
Tape feeder in lowered
position
not connected
not connected
connected
Upper machine head pcb is
not connected
Lower machine head pcb is
not connected
Right thread tension pcb is
not connected
sor pcb not connected
Needle Transport PCB not
connected
Edge guide pcb is not
connected
Edge guide x-axis pcb is not
connected
Corrective
• Check connection cables
• Perform software update
• Replace the control of the tape feeder
• Tape Feeder not in lowered position
• Check connection cables
• Perform software update
• Replace material thickness sensor
• Check connection cables
• Perform software update
• Replace remaining thread monitor
• Check connection cables
• Perform software update
• Replace remaining thread monitor
• Check connection cables
• Perform software update
• Replace PCB
• Check connection cables
• Perform software update
• Replace PCB
• Check connection cables
• Perform software update
• Replace PCB
• Check connection cables
• Perform software update
• Replace thread tension sensor
• Check connection cables
• Perform software update
• Replace needle transport PCB
• Check connection cables
• Perform software update
• Replace PCB
• Check connection cables
• Perform software update
• Replace PCB
Operating Instructions D888 e-con - 00.0 - 12/2023