Code
Type
1004
Error
1005
Error
1006
Error
1007
Error
1008
Error
1010
Error
1011
Error
1012
Error
1054
Error
1055
Error
1060
Error
206
Possible cause
Incorrect sewing motor
direction of rotation
Motor blocked
Maximum speed exceeded
Error in the reference run
Encoder error
External synchronizer plug
X5T (Sub-D, 9-pin) not
connected
Encoder Z pulse missing
Synchronizer fault
Internal short circuit
Sewing motor overload
Sewing motor overload /
overvoltage /overcurrent
Corrective
• Replace encoder
• Check motor plug assignment and
change it if necessary
• Check wiring in machine distributor and
change it, if necessary
• Measure motor phases and check for
value
• Check for stiff movement
• Replace encoder
• Replace sewing motor
• Replace encoder
• Carry out a reset
• Check class (t 51 04)
• Replace encoder
• Check for stiff movement
• Replace encoder
• Connect cable of external synchronizer to
control, make sure that interface (Sync) is
correct
• Only recommended for machines with
transmission!
• Switch off the control, use handwheel to
turn, and switch on the control again
• If error is not corrected, check encoder
• Replace synchronizer
• Replace the control
• Check for stiff movement
• Replace encoder
• Replace sewing motor
• Check selection of class
• Replace the control
• Replace motor
• Replace encoder