Code
Type
2484
Error
2485
Error
2487
Error
2488
Error
2501
Error
2505
Error
2521
Error
2522
Error
2530
Error
2531
Error
2571
Error
2572
Error
Operating Instructions D888 e-con - 00.0 - 12/2023
Possible cause
Stepper card X60 parameter
initialization (Edge guide)
Stepper card X60 insulation
error (Edge guide)
Stepper card X60 transport
interval failure (Edge guide)
Stepper card X60 reference
drive failure (Edge guide)
Stepper card X70 reference
drive timeout (Upper puller)
Stepper card X70 stepper
motor blockage (Upper
puller)
Stepper card X70 encoder
plug (Sub-D, 9-pin) not
connected
Stepper card X70 flywheel
position not found
Stepper card X70 not
responding
Stepper card X70 initializa-
tion failure
Stepper card X70 watchdog
(Upper puller)
Stepper card X70 motor
overload/overvoltage/over-
current (Upper puller)
Corrective
• Perform software update
• Check selection of class
• Check motor phase and PE for low-
impedance connection
• Replace encoder
• Replace sewing motor
• Perform software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Check reference sensor
• Check for stiff movement
• Connect encoder cable to the control, use
correct connection
• Check stepper motor 1 for stiff movement
• Perform software update
• Replace the control
• Perform software update
• Check selection of class
• Perform software update
• Check selection of class
• Check selection of class
• Replace the control
• Replace encoder
• Replace stepper motor