Dürkopp Adler D888 e-con Operating Instructions Manual page 224

Table of Contents

Advertisement

Code
Type
6070
Error
6353
Error
6360
Information No valid data on external
6361
Information No external EEprom con-
6362
Information No valid data on internal
6363
Information No valid data on internal and
6364
Information No valid data on internal
6365
Information Internal EEprom defective
6366
Information Internal EEprom defective
6367
Information Internal EEprom defective
222
Possible cause
Internal CAN
EEprom Timeout
EEprom (internal data struc-
tures are not compatible with
the external data storage
device)
nected
EEprom (internal data struc-
tures are not compatible with
the external data storage
device)
external EEprom (software
version is not compatible
with the internal data storage
device, emergency operat-
ing features only)
EEprom and no external
EEprom connected
(the internal data structures
are not compatible with the
external data storage
device)
and external data not valid
(emergency operating
features only)
and external data not valid
(emergency operating
features only)
Corrective
• Perform software update
• Replace the control
• Switch off the control, wait until the LEDs
are off, check connection for machine ID,
and switch on control again
• Software update
• Connect machine ID
• Check machine ID connection
• Switch off the control, wait until the LEDs
have gone out, and then switch on the
control again
• Software update
• Check machine ID connection
• Switch off the control, wait until the LEDs
have gone out, and then switch on the
control again
• Software update
• Check machine ID connection
• Switch off the control, wait until the LEDs
have gone out, and then switch on the
control again
• Software update
• Replace the control
• Replace the control
• Replace the control
Operating Instructions D888 e-con - 00.0 - 12/2023