Dürkopp Adler D888 e-con Operating Instructions Manual page 219

Table of Contents

Advertisement

Troubleshooting
Code
Type
2588
Error
2601
Error
2605
Error
2621
Error
2622
Error
2630
Error
2631
Error
2671
Error
2672
Error
2673
Error
2674
Error
2675
Error
2676
Error
Operating Instructions D888 e-con - 00.0 - 12/2023
Possible cause
Stepper card X70 reference
drive failure (Upper puller)
Stepper card X80 reference
run timeout (Bottom puller)
Stepper card X80 stepper
motor blockage (Bottom
puller)
Stepper card X82 encoder
plug (Sub-D, 9-pin) not
connected (Bottom puller)
Stepper card X80 flywheel
position not found (Bottom
puller)
Stepper card X80 not
responding (Bottom puller)
Stepper card X80 initializa-
tion failure (Bottom puller)
Stepper card X80 watchdog
(Bottom puller)
Stepper card X80 motor
overload/overvoltage/over-
current (Bottom puller)
Stepper card X80 sewing
motor encoder not connected
(Bottom puller)
Stepper card X80 sewing
motor encoder not initialized
(Bottom puller)
Stepper card X80 init
position not found
(Bottom puller)
Stepper card X80 not
enabled (Bottom puller)
Corrective
• Check for stiff movement
• Replace encoder
• Replace motor
• Check reference sensor
• Check for stiff movement
• Connect encoder cable to the control,
use correct connection
• Check stepper motor 6 for stiff movement
• Perform software update
• Replace the control
• Perform software update
• Check selection of class
• Perform software update
• Check selection of class
• Check selection of class
• Replace the control
• Replace encoder
• Replace stepper motor
• Replace the control
• Perform software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
217