Code
Type
2205
Error
2221
Error
2222
Error
2230
Error
2231
Error
2252
Error
2271
Error
2272
Error
2273
Error
2274
Error
2275
Error
2276
Error
2277
Error
210
Possible cause
Stepper card X40 stepper
motor blockage
Stepper card X40 encoder
plug (Sub-D, 9-pin) not
connected
Stepper card X40 flywheel
position not found
Stepper card X40 not
responding
Stepper card X40 initializa-
tion failure
Stepper card X40
overcurrent
Stepper card X40 watchdog
(Foot lifting)
Stepper card X40 motor
overload/overvoltage/over-
current (Foot lifting)
Stepper card X40 sewing
motor encoder not con-
nected (Foot lifting)
Stepper card X40 sewing
motor encoder not initialized
(Foot lifting)
Stepper card X40 init position
not found (Foot lifting)
Stepper card X40 not
enabled (Foot lifting)
Stepper card X40 I²t
(Foot lifting)
Corrective
• Check for stiff movement
• Connect encoder cable to the control, use
correct connection
• Check stepper motor 1 for stiff movement
• Perform software update
• Replace the control
• Perform software update
• Check selection of class
• Check for stiff movement
• Perform software update
• Check selection of class
• Check selection of class
• Replace the control
• Replace encoder
• Replace stepper motor
• Replace the control
• Perform software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
• Check for stiff movement
• Replace encoder
• Replace motor