Dürkopp Adler D888 e-con Operating Instructions Manual page 155

Table of Contents

Advertisement

Programming Commander DELTA
Operating Instructions D888 e-con - 00.0 - 12/2023
Icon
Menu item
Switch-off delay
Seams
Input of the number of signal detections
after which the machine is supposed
to continue with the specifically set
parameters.
Filter stitches
Loosely woven fabric with stitches may
cause the light barrier to wrongly detect
a signal. To prevent this from happening,
you enter the number of filter stitches.
This number represents the minimum
number of stitches with signal detection
following the 1
5.9.7.3 Parameters Thread tension sensor mode
Icon
Menu item
Lower limit
Upper limit
Thread tension warning delay stitches
If the specified maximum of allowed
faulty values is exceeded multiple times
in a row, the software outputs a warning.
Allowed faulty TT values per seam
If the specified maximum of allowed
faulty values is exceeded in the entire
seam, the software outputs a warning.
st
detection of the signal.
Settings
Value range
0 – 9999 [mm]
Value range
1 – 255
Value range
0 – 255
Setting
Value range
0000 – 1100
Value range
0000 – 1100
Value range
000 – 100
Value range
000 – 100
153