Programming
Icon
Parameter
Seam begin bartack settings
Bartack at seam begin
Number of stitches backwards
Number of stitches forward
Number of bartack sections
A bartack consists of several sections.
If the sewing direction is changed, a new
section is started. The number of sections
in a bartack can be set here.
Operating Instructions D669 M-TYPE DELTA - 00.0 - 10/2020
Setting options Max. sewing speed
Menu item Setting 1
linear
Max.
Sewing speed
Value range 0000 – 4000
Min. Material
thickness
Value range 00.0 – 10.0 [mm]
Max. Material
thickness
Value range 00.0 – 10.0 [mm]
5.8.6
Setting the Seam Begin/Segment Begin
parameters
There are various options for setting the Seam Begin/Segment
Begin parameters. The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
Setting 2
Maximum speed reached
at the upper material
thickness limit.
Material thickness at which
the increase in sewing
speed should start.
Material thickness up to
which the increase in sew-
ing speed should occur.
Setting
Value range
On/Off
Value range
01 - 50
Value range
01 - 50
Value range
01 - 99
117