Setting The Segment Parameters - Dürkopp Adler D888 e-con Operating Instructions Manual

Table of Contents

Advertisement

Icon
Parameter
Seam Parameter
Stitch length
Needle thread tension
Top fullness
Bottom fullness
Fullness type
Max. Speed
It is possible to reduce the maximum
sewing speed at this point.
The maximum sewing speed can be
set in the software at the Technician
level.
Sewing foot lift at stop
114
5.7.5

Setting the Segment parameters

There are various options for setting the parameters in the segment.
The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
Programming Commander DELTA
Settings
Value range
00.0 – 12.0 [mm]
(depending on the sewing equipment
and the subclass)
Value range
01 – 99 [%]
Value range
-06 – 16
Value range
-06 – 16
Value range
Top/Bottom
Value range
0150–2500 [rpm]
(depending on subclass)
Value range
On/Off
Operating Instructions D888 e-con - 00.0 - 12/2023

Advertisement

Table of Contents
loading

Table of Contents