Dürkopp Adler D888 e-con Operating Instructions Manual page 154

Table of Contents

Advertisement

152
5.9.7.2 Setting the Light barrier parameters
The light barrier detects the beginning and the end of the material.
After a signal was detected, sewing can continue automatically
with the specifically set parameters.
Icon
Menu item
Distance
Distance from the detection of the signal
to the end of the material.
The distance signifies the path from the
needle to the light barrier. The path is
specified in millimeters and used by the
machine to independently calculate the
number of stitches.
Signal detection at seam begin
The signal scan of the light barrier is
performed at the beginning of the seam.
If the function is activated, the light
barrier must detect a signal to allow
the machine to sew.
If the function is inactive, sewing can
take place without signal detection.
Signal detection at seam end
The signal scan of the light barrier is
performed at the end of the seam. If the
function is active, the machine will
continue to sew with the specifically
set parameters following the signal
detection. If the function is inactive,
nothing will happen.
Start after bartack
Start delay
Programming Commander DELTA
Operating Instructions D888 e-con - 00.0 - 12/2023
Settings
Value range
0 – 255 [mm]
Value range
On/Off
Value range
On/Off
Value range
On/Off
Value range
0 – 9999 [mm]