13;
D
Dial Telephone Number
Which dial type should be used
The modem can dial numbers according to two different
standards: Touch tone dial (modifier T) and Pulse dial (P).
When possible tone dial should be used. It is faster and it is an
international standard.
Pulse dial may be used if tone dial is not accepted (Typical for
old PABX equipment.)
Using neither of the two dial modifiers T nor P, the modem will
use the most recently used modifier.
Blacklisting:
Blacklisting is a country dependent function and this text only
applies for use in Norway.
1. There will always be a delay of 8 seconds between each
repeated calls. The modem inserts this delay if necessary.
2. Maximum 7 retries to the same number are allowed within a
period of 10 min. The number will be blacklisted for 30 min. if
the maximum number of retries is exceeded. When a
call to a
blacklisted number is initiated the following result code will be
given:
ERROR
(If +Q0 is active)
BLACK LISTED NUMBER (if +Q3 is active)
3. All calis that fails with the resultcode NO CARRIER or BUSY
will be stored for control of radialling. The total storage
capacity for this storage is 200 characters. Each stored
number consists of 7 characters in addition to the dialling
sequence. The modem will deny calling any number when
limit of 200 characters stored is reached and indicates this by
result code:
ERROR
(If +Q0 is active)
BLACK LIST TABLE IS FULL, RESET MODEM (If +Q3 is active)