Ericsson ZAT 19.2 Operation Manual page 108

Table of Contents

Advertisement

Default:
43,
which is the ASCII code for + .
Range:
0-255
The Escape code is now #, which
is ASCII
code 23.
. | If you use the command ###,
causes the
'|modem to return from data to command mode,
[without going on hook
The S2 value may be between 0 and 255.
However, values
greater than 127 will disable the "escape" - sequence, as it will
not be registered by the modem.
Return to command state can
now only take place if the remote modem disconnects, causing
the carrier to disappear.
If either of &D1, &D2 or &D3 commands is used, the modem will
return to command
state when detecting DTR ON/OFF.
$3
Carriage return
Default:
13
(can be changed if the DTE is other than standard type )
Range:
0-127 ASCIil
Used to end command strings
S4
Line feed
Default:
10
Range:
0-127 ASCII
Line feed is a check symbol following Carriage Return when
verbal result codes are being used.
S5
Back space
Default:
8.
Range:
0-127 ASCII
The value must not represent an ASCII character greater than
33.
4-4
LZTR104006 R1.00
Zat 14.4/14.4-7 and 19.2/19.2-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zat 19.2-7Zat 14.4Zat 14.4-7

Table of Contents