6.6
Examples
6.6.1
Password protected system,
Password table operated only at local site.
= Enter passwords for users all with access level 0
AT+P=SMITH: 473701 171 oe
= Set
mode to only local operation
of password commands
protected by physical access to the modem
(switch toggle)
AT+PA3 6,
=Set modem to auto answer the simulated RING Sequence.
Remote commands can now be enabled (+01,+02,+03) but
password commands can not be executed from remote site.
Any attempt to use of +P commands from remote site will cause
the ERROR resultcode to be given when +PA2 or +PA3 is used.