_4. Registers " |
+S45
Line quality limit during handshake'
Default:
70
Range:
0 - 255
Unit.
EQM
Defines the line quality limit for fallback during V.32/V.32 bis
handshake. A higher value makes the modem more likely to
handshake at the highest speed.
+S46
Line quality limit for fallforward
Default:
20.
Range:
0-255.
Unit: EQM
Defines the line quality limit for fallforpward. When setting this
value higher the modem will accept poorer lines before doing a
fallback.
+S47
Line quality response time for fallforward
Default:
92. (59 seconds).
Range:
1-255.
Unit:0.64
Specifies the fallforward response time when experiencing better
line quality.
+S48
LPDA2 Address
Default:
FF hex
+S49
Bit mapped used by LPDA function
Default:
00 hex
+S$50
Bit mapped options
Binary code: x000 000C
BitO
|Handshake according |
0] (+&HMO) | Handshake will
to V.25
start after detection of V.25
answer lone when manual
connection
(+&HM1) | Handshake will
start direct with no answer
tone detection
Bit 1-6 | Not used
Bit7
|Select transmit clock | 0} (+&WO)/+/-100
tracking
1 (+&W1) | +/-200