16.2 Summary S- registers
16.2.1
S- register:
$
N
0-
Ringsignals
Auto answer on/off
0-255
Ringsignals
Ring counter
0-255
ASCII
Escape Sequence
Code (+++)
$3
[0-127
ASCII
13
Carriage return
$4
|0-127
ASCII
10
Line feed
S5
{0-127
ASCII
08
Back space
$6
[2-10
Seconds
02*
Wait time blind dial
$7
{0-60
Seconds
50*
Wait time for Carrier
ss
{0-10
Seconds
02*
Pause time for ,
(comma).
$9
[1-255
1/10 second
06
Carrier detect
Response time
$10
{1-255
1/10 second
01
Lost carrier lo hang-up
delay
$11
{70-130
milsec.
100*
DTMF Dialling speed
$12
|0-255
1/50 second
50
Escape Sequence
code guard time
$13
Not used
$14
}x0x0 100
Binary
8A hex" | Bit mapped options
$15
Not used
$16
|OCCC ACOC
Binary
00
Test mode status
$17
Not used
$18 | 0-255
Seconds
00
Test timer
$19/
Not used
$20
S21 | 00xx xx00
Binary
20 hex | Bit mapped options
$22 | Oxxx xx00
Binary
74 hex* | Bit mapped options
$23 | xx00 000x
Binary
81 hex* | Bit mapped options
$24
Not used
$25
|0-255
1/100 second
| 05
DTR delay
$26
[0-255
1/100 second
{01
RTS to CTS delay
$27 | Ox Or00x
Binary
00 hex | Bit mapped options
* " See 16.5 for more information aboul (he parameters for different countries.